TJS TurboFlux Journal System TurboFlux Journal System
Open Access Peer Reviewed ISSN: 2992-4383
Research article open Vol. 11 No. 1 (2015)

APPRAISAL OF POWER GENERATION CAPABILITY OF IBOM POWER STATION

N. O. Ubani, B.N. Nwankwojike, J.E Dara, A.C Ubani, U. I. Fredrick · September 1, 2016

ISSN 2992-4383

Authors

  • N. O. Ubani Corresponding author
  • B.N. Nwankwojike
  • J.E Dara
  • A.C Ubani
  • U. I. Fredrick

Abstract

This research paper evaluates the power generation capability of Ibom Power Station – a gas thermal station in Nigeria with total installed capacity of 190 MW. The performance indices (capacity factor, use factor, utilization factor, and availability factor) assessed showed that the power station obviously operates well below installed capacity. The study further reveals that 42.48% of the installed capacity was available. The utilization and use factor ranged from 46.50% to 92.46% for the period reviewed. Also the heat rate of the plant was obtained. An empirical model was developed to predict the monthly power generation of the power station to enable the management of the power station and the National Control Centre (NCC) plan effectively for inventory and production. It was also observed that the power station does not aim to operate at full capacity rather to meet with the demand of the NCC.

Keywords

Energy, Power plant factor, Efficiency, Gas Turbine, Power Generation, Performance.

How to cite

No formats match your search.

Pick a style from the searchable list. Download uses the format currently selected.

Reference managers: RIS · BibTeX · EndNote

In-text (APA): (Ubani et al., 2016) · Ubani et al. (2016)