TJS TurboFlux Journal System TurboFlux Journal System
Open Access Peer Reviewed ISSN: 2992-4383
Research article open Vol. 6 No. 5 (2026)

Influence of Hydraulic Parameters on Organic Load Removal from Abattoir Wastewater Using Alginate-Mushroom Bioremediation Membrane in a Continuous Packed-Bed Bioreactor

Chioma Mary John, Sunday Uzochukwu John, Matthew Chukwudi Menkiti · Pages 4266-4276 · October 17, 2026

ISSN 2992-4383

Authors

  • Chioma Mary John Corresponding author
  • Sunday Uzochukwu John
  • Matthew Chukwudi Menkiti

Abstract

Abattoir wastewater contains elevated biochemical oxygen demand (BOD) and chemical oxygen demand (COD), posing serious environmental risks when discharged untreated. Conventional treatment methods suffer from high energy demand, excessive sludge production and incomplete organic-load removal. This study evaluated the effects of flow rate (1.9–17.9 mL min⁻¹) and packing height (1–5 cm) on BOD and COD reduction in real abattoir wastewater using an alginate-mushroom bioremediation membrane (AMBM) in a continuous packed-bed bioreactor. The AMBM was prepared by immobilising Pterocarpus mildbraedii mushroom biomass (PMMB) in sodium alginate with solvent-free naphthalene sublimation to enhance porosity. Continuous-flow experiments were performed at contact times of 5–35 min. Both hydraulic variables positively influenced performance. At 35 min, BOD reduction increased from 73.5 % to 96.4 % and COD reduction from 73.6 % to 95.6 % as flow rate rose from 1.9 to 17.9 mL min⁻¹. Increasing packing height from 1 cm to 5 cm raised BOD reduction from 61.9 % to 96.0 % and COD reduction from 54.2 % to 96.0 %. ANOVA and Tukey’s HSD tests confirmed that packing height had a highly significant effect on both responses (p ≤ 0.002), while flow rate significantly affected BOD reduction (p = 0.012). Maximum efficiencies were obtained at 17.9 mL min⁻¹ and 5 cm packing height. The novelty of this work lies in the systematic quantification of the individual and comparative effects of flow rate and packing height on simultaneous BOD and COD removal using a solvent-free, porogen-enhanced alginate-fungal membrane under continuous operation—a gap largely unaddressed in the literature. The results demonstrate that AMBM is effective for continuous abattoir wastewater treatment when hydraulic conditions are properly selected, with packing height providing the greater process leverage.

Keywords

Alginate-mushroom bioremediation membrane; Pterocarpus-mildbraedii mushroom biomass, Abattoir wastewater; BOD reduction; COD reduction; Flow rate; Packing height; Continuous packed-bed bioreactor

How to cite

No formats match your search.

Pick a style from the searchable list. Download uses the format currently selected.

Reference managers: RIS · BibTeX · EndNote

In-text (APA): (John et al., 2026) · John et al. (2026)