TJS TurboFlux Journal System TurboFlux Journal System
Open Access Peer Reviewed ISSN: 2992-4383
Research article open Vol. 6 No. 3 (2026)

Low-Carbon Reinforced Concrete Beams Using Recycled-Aggregate Concrete and Industrial-Waste Binders: Experimental Bond-Strength and Flexural Performance Assessment

Unamba K.U., Medjor E.A. · Pages 3678-3690 · July 2, 2026

ISSN 2992-4383

Authors

  • Unamba K.U. Corresponding author
  • Medjor E.A.

Abstract

The construction sector is one of the largest contributors to global carbon dioxide emissions, with Portland cementproduction accounting for roughly 8% of anthropogenic CO2 annually. This paper presents an experimental investigationinto the bond strength and flexural performance of reinforced concrete beams made from recycled coarse aggregateconcrete incorporating industrial-waste supplementary cementitious materials, specifically ground granulated blastfurnaceslag conforming to EN 15167-1, fly ash conforming to EN 450-1, and silica fume conforming to EN 13263-1.Four concrete mixes were evaluated: a normal concrete control, two recycled aggregate concrete mixes with 50% and100% coarse aggregate replacement, and a blended-binder mix with 100% recycled aggregate and combinedsupplementary cementitious material substitution of 44.4% by cement mass. Beams measuring 150 mm x 250 mm x 2000mm were tested under four-point bending at 28 days, with companion cylinder and pull-out specimens tested in parallel.The characteristic compressive strength of the 100% recycled aggregate mix fell 15.8% below the normal concrete control(34.7 vs. 41.2 MPa), while the blended-binder mix surpassed normal concrete by 5.6% at 43.5 MPa. Experimental bondstrength in the blended-binder mix reached 10.53 MPa, exceeding normal concrete by 7.0%, while the 100% recycledaggregate mix showed a 16.6% reduction. Eurocode 2 design bond values proved conservative relative to measured resultsacross all mixes, with the fib Model Code 2010 showing markedly closer agreement. The blended-binder mix achieved anultimate load of 134.7 kN and a ductility index of 4.12 against normal concrete's 3.41. Embodied carbon analysis confirmeda 28.3% reduction for the blended-binder mix relative to the normal concrete control.

Keywords

Recycled aggregate concrete; supplementary cementitious materials; Eurocode 2; bond strength; flexural performance; interfacial transition zone; embodied carbon

How to cite

No formats match your search.

Pick a style from the searchable list. Download uses the format currently selected.

Reference managers: RIS · BibTeX · EndNote

In-text (APA): (K.U. & E.A., 2026) · K.U. and E.A. (2026)